Allowable Amperage for UL 1426 Boat Cable |
||||||||||||||
When no more than 2 current |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18 AWG |
16 AWG |
14 AWG |
12 AWG |
10 AWG |
8 AWG |
6 AWG |
4 AWG |
2 AWG |
1AWG |
1/0AWG |
2/0AWG |
3/0AWG |
4/0 AWG |
Outside Engine space |
20 |
25 |
35 |
45 |
60 |
80 |
120 |
160 |
210 |
245 |
285 |
330 |
385 |
445 |
Inside Engine space |
17 |
21.3 |
29.8 |
38.3 |
51 |
68 |
102 |
136 |
178.5 |
208.3 |
242.3 |
280.5 |
327.3 |
378.3 |
When 3 current carring coductors are bundled |
|
|
|
|
|
|
|
|
|
|
|
|||
|
18 AWG |
16 AWG |
14 AWG |
12 AWG |
10 AWG |
8 AWG |
6 AWG |
4 AWG |
2 AWG |
1AWG |
1/0AWG |
2/0AWG |
3/0AWG |
4/0 AWG |
Outside Engine space |
14 |
17.5 |
24.5 |
31.5 |
42 |
56 |
84 |
112 |
147 |
171.5 |
199.5 |
231 |
269.5 |
311.5 |
Inside Engine space |
11.9 |
14.9 |
20.8 |
26.8 |
35.7 |
47.6 |
71.4 |
95.2 |
125 |
145.8 |
169.6 |
196.4 |
229.1 |
264.8 |
When 4 to 6 current carring coductors are bundled |
|
|
|
|
|
|
|
|
|
|
|
|||
|
18 AWG |
16 AWG |
14 AWG |
12 AWG |
10 AWG |
8 AWG |
6 AWG |
4 AWG |
2 AWG |
1AWG |
1/0AWG |
2/0AWG |
3/0AWG |
4/0 AWG |
Outside Engine space |
12 |
15 |
21 |
27 |
36 |
48 |
72 |
96 |
126 |
147 |
171 |
198 |
231 |
267 |
Inside Engine space |
10.2 |
12.8 |
17.9 |
23 |
30.6 |
40.8 |
61.2 |
81.6 |
107.1 |
125 |
145.4 |
168.3 |
196.4 |
227 |
When 7 to 24 current carring coductors are bundled |
|
|
|
|
|
|
|
|
|
|
|
|||
|
18 AWG |
16 AWG |
14 AWG |
12 AWG |
10 AWG |
8 AWG |
6 AWG |
4 AWG |
2 AWG |
1AWG |
1/0AWG |
2/0AWG |
3/0AWG |
4/0 AWG |
Outside Engine space |
10 |
12.5 |
17.5 |
22.5 |
30 |
40 |
60 |
80 |
105 |
122.5 |
142.5 |
165 |
192.5 |
222.5 |
Inside Engine space |
8.5 |
10.6 |
14.9 |
19.1 |
25.5 |
34 |
51 |
68 |
89.3 |
104.1 |
121.1 |
140.3 |
163.6 |
189.1 |
Allowable Amperage for class 60 ℃ Shipboard Cable Based on ambient temperature 45 ℃ |
|||||||||||||
|
1.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
10mm2 |
16mm2 |
25mm2 |
35mm2 |
50mm2 |
70mm2 |
95mm2 |
120mm2 |
150mm2 |
Single Core |
12 |
17 |
22 |
29 |
40 |
54 |
71 |
87 |
105 |
135 |
165 |
190 |
220 |
2 Core |
10 |
14 |
19 |
25 |
34 |
46 |
60 |
74 |
89 |
115 |
140 |
162 |
187 |
3 or 4 Core |
8 |
12 |
15 |
20 |
28 |
38 |
50 |
61 |
74 |
95 |
116 |
133 |
154 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Allowable Amperage for class 70 ℃ Shipboard Cable Based on ambient temperature 45 ℃ |
|||||||||||||
|
1.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
10mm2 |
16mm2 |
25mm2 |
35mm2 |
50mm2 |
70mm2 |
95mm2 |
120mm2 |
150mm2 |
Single Core |
15 |
21 |
29 |
37 |
51 |
68 |
90 |
111 |
138 |
171 |
207 |
239 |
275 |
2 Core |
13 |
18 |
25 |
31 |
43 |
58 |
77 |
94 |
117 |
145 |
176 |
203 |
234 |
3 or 4 Core |
11 |
15 |
20 |
26 |
36 |
48 |
63 |
78 |
97 |
120 |
145 |
167 |
193 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Allowable Amperage for class 85 ℃ Shipboard Cable Based on ambient temperature 45 ℃ |
|||||||||||||
|
1.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
10mm2 |
16mm2 |
25mm2 |
35mm2 |
50mm2 |
70mm2 |
95mm2 |
120mm2 |
150mm2 |
Single Core |
20 |
28 |
38 |
48 |
67 |
90 |
120 |
145 |
180 |
225 |
275 |
320 |
365 |
2 Core |
17 |
24 |
32 |
41 |
57 |
77 |
102 |
123 |
153 |
191 |
234 |
272 |
310 |
3 or 4 Core |
14 |
20 |
27 |
34 |
47 |
63 |
84 |
102 |
126 |
158 |
193 |
224 |
256 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Allowable Amperage for class 90 ℃ Shipboard Cable Based on ambient temperature 45 ℃ |
|||||||||||||
|
1.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
10mm2 |
16mm2 |
25mm2 |
35mm2 |
50mm2 |
70mm2 |
95mm2 |
120mm2 |
150mm2 |
Single Core |
21 |
30 |
40 |
51 |
71 |
95 |
125 |
155 |
190 |
240 |
290 |
340 |
385 |
2 Core |
18 |
25 |
34 |
43 |
60 |
81 |
105 |
135 |
165 |
200 |
|
|
|
3 or 4 Core |
15 |
21 |
29 |
36 |
50 |
67 |
89 |
105 |
135 |
170 |
205 |
240 |
270 |